Wuhan GDMK Electric Co., Ltd.

Wuhan Jiangxia District Bridge New District, Huangjiahu Avenue West color aluminum plastic steel doo, AC Resonant Test System For CVT, 430200

https://www.mktester.com/high-voltage-tester/series-resonance-test-device/ac-resonant-test-system-for-cvt.html





Product Introduction

Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer.

 

Product Parameters

Technical parameters

Rated Capacity80kVA
rated voltage160kV
Adjustable inductance range65~130H
Rated frequency50Hz
Rated current0.5A
Adjustable gap range0~300mm

Product Characteristics

  • 1?Due to full compensation of resonant reactive power the power of power supply and equipment is less than 1/10 of the required capacity of the subject (1/Q>10). Small size and light weight with the same capacity large output capacity of the device and small power capacity required cheap convenient and safe to use;

  • 2?Series resonance is actually a current filtering circuit so that the current passing through the subject is basically the fundamental current and the waveform distortion rate (THD) of the output voltage is very small which is superior to all existing ac voltage withstand equipment.

  • 3?The short circuit current of the sample after flashover or breakdown is only less than 1/10 (1/Q) of the test current before short circuit which can effectively prevent the expansion of damage to the fault point after breakdown;

  • 4?After flashover the arc will be automatically extinguished immediately. The long (number of seconds) process of restoring resonant state voltage after arc quenching is a steady-state establishment process and there is no danger of voltage overshoot and no danger of restoring overvoltage in microsecond millisecond transient process.
























5 out of 5 from 1 reviews

Write a review

Overal review:
Type your review:
(max 1000 characters)
Verification code:
electric in Single-phase Electric Meter Field Calibrator
https://www.mktester.com/power-analyzer/single-phase-electric-meter-field-calibrator.html ...
electric in High Pressure Wireless Phase Detector
https://www.mktester.com/electric-power-safety-tool/high-pressure-wireless-phase-detector.html

electric in High Pressure Wireless Phase Detector
https://www.mktester.com/electric-power-safety-tool/high-pressure-wireless-phase-detector.html ...
electric in Portable Single-phase Electric Meter Test Equipmen
https://www.mktester.com/power-analyzer/portable-single-phase-electric-meter-test.html