Wuhan GDMK Electric Co., Ltd.

Jiangxia District Huangjiahu Avenue West Color Aluminum Plastic Comprehensive Building, Transformer Integrated Test, Tes 430200

https://www.mktester.com/transformer-test-system/transformer-comprehensive-analyzer/transformer-integrated-test-test-bench.html

Transformer Integrated Test, Test Bench

Overview:

The transformer integrated test system produced by the company is mainly to test the no-load and load characteristics of the power transformer, the distribution transformer, and can also perform multiplier induction and power frequency withstand voltage test of the trial transformer. Transformer Comprehensive Test System Depending on the performance and parameter detection of the test system detection, transformer manufacturing process testing test and finished product testing test, research and testing unit design and transformation transformer verify its design to provide accurate parameters and data, indilla The demand of different units is directed to the development and design of multiple test functions of multiple test functions in transformers.



Technical parameter:

weightcustom made
Factory test and special test of 10kV, 20KV, 35KV, 110KV, 220kV, 330kV, 500KV, special transformer
System voltage measurement range5V~500kV
Test equipment measurement range5V ~ 1000V, measurement equipment has 100V, 500V, 750V, 1000V multiple measurement range equipment optional
Voltage Transformer (PT) Measurement10V ~ 500kV, transformer range is customized according to the test demand, can be 1000kV, measurement accuracy is 0.05%
Current metering range0.1A~2000A
Test equipment measurement range0.1A ~ 20A; Impatings 1A, 5A, 20A can be selected; measurement accuracy 0.1%
Current Transformer (PT) Measurement0.1a to 2000a, transformer range is customized according to the test requirements, can be 5000A; measurement accuracy is 0.05%
Frequency Range=400Hz, regular frequency is: 50Hz, 60Hz, 100Hz, 150Hz, 200Hz
Power metering accuracy0.1% of metering equipment, 0.05% system accuracy of transformers 0.2%
Input voltage monitoring instrumentSurveillance range=600V
Instrumentation accuracy0.2%
Input current monitoring instrumentSurveillance range=2000A
Instrumentation accuracy0.2%
Monitoring instrument frequency=400Hz, regular frequency: 50Hz, 60Hz, 100Hz, 150Hz, 200Hz



Function:

The test area monitoring function can be accessed in the operation room to fully understand the work status of the test in the test area, to ensure equipment and personnel safety;

      Perfect overvoltage overcurrent protection;

      The regulator zero detection, only the regulator can start the device function, take care of people and equipment security in zero.

  Equipment failure automatic detection function, automatically detect peripherals, such as: the voltage regulator is zero, etc .;