Product description:

Electrical equipments in modern industrial, commercial and residential users are more sensitive to power quality, and have a higher requirement of quality of power supply. Currently, harmonics,electromagnetic interference, power factor reduction have been tied to the three hazard of the power system.

When it is interfered or contaminated, grid power quality can’t reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country.


3 phase handheld power quality analyzer Technical index:

1. Input characteristics

Voltage measuring range: 0~200V~800V, automatic cutting gear.

Current measurement range

Clamp transformers (three types): 5A / 25A (standard)

100A / 500A (optional)

400A / 2000A (optional)

Phase angle measuring range: 0 ~ 359.99 °.

Frequency measurement range: 45 ~ 55Hz.

Voltage channels: three-channel (UA?UB?UC).

Current channels: three-channel (IA?IB?IC).

Maximum harmonic analysis times: 63 times.

Maximum continuous storage period in 1 minute interval: 18 months.

2. Accuracy

Measurement of electrical parameters section:

Voltage: ± 0.2%

Frequency: ± 0.01Hz

Current, power: ± 0.5%

Phase: ± 0.2 °

Power quality section:

Fundamental voltage tolerance: =0.5% F.S.

Fundamental current tolerance: =1% F.S.

Phase between fundamental voltage and current measurement error: =0.2 °

Percentage of harmonic voltage measurement error: =0.1%

Percentage of harmonic current measurement error: =0.2%

Three phase voltage unbalance error: =0.2%

Voltage deviation error: =0.2%

Voltage fluctuation error: =0.2%

3. Working temperature: -10 ? ~ + 40 ?

4. Charging Power: 220V AC, 45Hz-55Hz frequency

5. Host Power: =3VA

6. Battery maximum working time: =10 hours

7. Insulation:

1) The insulation resistance between the voltage, current input terminal and the housing =100MO.

2) Withstand 1.5KV (valid value) with power frequency on operating power input and the shell, which lasts one minute.

8. Size: 258mm × 158mm × 58mm

9. Weight: 1.8Kg







5 out of 5 from 1 reviews

Write a review

Overal review:
Type your review:
(max 1000 characters)
Verification code:
electric in Single-phase Electric Meter Field Calibrator
https://www.mktester.com/power-analyzer/single-phase-electric-meter-field-calibrator.html ...
electric in High Pressure Wireless Phase Detector
https://www.mktester.com/electric-power-safety-tool/high-pressure-wireless-phase-detector.html

electric in High Pressure Wireless Phase Detector
https://www.mktester.com/electric-power-safety-tool/high-pressure-wireless-phase-detector.html ...
electric in Portable Single-phase Electric Meter Test Equipmen
https://www.mktester.com/power-analyzer/portable-single-phase-electric-meter-test.html